What Are Cp and Cpk? Process Capability

What Are Cp and Cpk? Process Capability

Cp and Cpk are process capability indices that express, in a single number, a production process’s ability to make products within the customer’s tolerance limits. Cp shows whether the process spread fits within the tolerance range, while Cpk also accounts for a shift in the process centre and shows how much of it actually stays within tolerance.

In brief

  • Cp = (USL − LSL) / 6σ; Cpk = min[(USL − X̄) / 3σ, (X̄ − LSL) / 3σ].
  • They are unitless; the higher the value, the more comfortably the process fits the tolerance.
  • Common acceptance: Cpk ≥ 1.33 adequate, ≥ 1.67 expected for new processes, < 1.00 inadequate.
  • They are meaningful only for a process in statistical control (stable).
  • Used by quality engineers, in PPAP files and in customer audits.

What Is Process Capability?

A control chart tells you whether the process is stable; capability tells you whether a stable process meets the tolerances. They are different questions. A process can be completely stable and constantly produce out of tolerance (stable but incapable), or meet the tolerance while being unstable. A capability calculation is meaningful only after stability is confirmed with SPC.

Cp: Potential Capability

Cp divides the tolerance width by the process’s natural spread (6 sigma):

Cp = (USL − LSL) / 6σ

Here USL is the upper and LSL the lower tolerance limit, and σ is the process standard deviation. If Cp = 1, the process spread is exactly as wide as the tolerance range; if Cp = 2, the tolerance is twice the process spread. Cp does not consider centring: even if the process has shifted completely out of tolerance, Cp does not change. That is why it is called “potential” capability.

Cpk: Actual Capability

Cpk divides the distance from the process mean to the nearest tolerance limit by 3 sigma and takes the smaller value:

Cpk = min [ (USL − X̄) / 3σ , (X̄ − LSL) / 3σ ]

If the process is in the middle of the tolerance, Cpk = Cp. As the centre shifts, Cpk falls. If Cp is high and Cpk is low, the problem is not the spread but the setting; centring the machine is enough. If Cp is also low, the spread must be reduced, which is usually harder and more expensive.

Threshold Values

CpkInterpretationApproximate out-of-tolerance rate (centred, normal distribution)
< 1.00Inadequate; out-of-tolerance production exists> 0.27%
1.00Borderline; ±3σ just touches the tolerance0.27% (2,700 ppm)
1.33Adequate (common minimum acceptance)≈ 63 ppm
1.67Good; expected for new processes and critical characteristics≈ 0.6 ppm
2.00Six sigma level≈ 0.002 ppm

A Worked Example

For the wall thickness of an injection-moulded part, LSL = 4.90 mm and USL = 5.10 mm. From a stable process, X̄ = 5.03 mm and σ = 0.02 mm are calculated.

  • Cp = (5.10 − 4.90) / (6 × 0.02) = 0.20 / 0.12 = 1.67
  • Upper side: (5.10 − 5.03) / (3 × 0.02) = 0.07 / 0.06 = 1.17
  • Lower side: (5.03 − 4.90) / (3 × 0.02) = 0.13 / 0.06 = 2.17
  • Cpk = min(1.17; 2.17) = 1.17

Interpretation: The process spread is adequate (Cp 1.67), but the centre has shifted 0.03 mm upwards. Moving the setting to 5.00 mm brings Cpk up to 1.67 as well; no new mould or machine is needed.

Cp/Cpk vs Pp/Ppk

In Cp and Cpk calculations, sigma is derived from within-subgroup spread (R̄/d₂ estimate) and shows short-term capability. Pp and Ppk use the standard deviation of all data and include long-term effects such as shifts, raw material lots and seasons. If Cpk is 1.6 while Ppk is 1.1, the process is good in the moment but drifts over time; the problem is not the machine but between lots or shifts.

Common Mistakes

  • Calculating Cpk for an unstable process; the number is meaningless and misleading.
  • Calculating with little data (for example 10 measurements) and assuming it is reliable; at least 100 data points are recommended.
  • Using the standard formula for non-normal distributions (one-sided tolerances such as flatness or eccentricity).
  • Reporting Cp and hiding Cpk.
  • Calculating with an uncalibrated measuring instrument; measurement error mixes into sigma.

Frequently Asked Questions

What is the difference between Cp and Cpk?
Cp looks only at spread: how many times does the process distribution fit into the tolerance range? Cpk also accounts for how far the process centre is from the middle of the tolerance. If the process is perfectly centred, Cp = Cpk; as the centre shifts, Cpk falls while Cp stays the same.
What should Cpk be?
The common industry acceptance in series production is Cpk ≥ 1.33; in automotive, 1.67 is required for new processes. Cpk = 1.00 means the process’s ±3 sigma just touches the tolerance limit and is considered inadequate in practice. Below 1 means out-of-tolerance production.
What is the difference between Pp/Ppk and Cp/Cpk?
Cp/Cpk use short-term spread (within-subgroup sigma) and show the process’s potential. Pp/Ppk are calculated with the standard deviation of all data and show actual long-term performance. A big gap between Cpk and Ppk means the process is not stable.

Cp and Cpk in EFFIX MES

EFFIX MES automatically calculates Cp and Cpk from the measurements collected for each characteristic in the control plan and shows them on the same screen as I-MR / X̄-R control charts, so capability is interpreted only with stable process data. Values can be filtered by machine, product, shift or lot and exported in a format suitable for customer audits with the flexible report designer. Notifications can be defined through the Proactive Alert System when capability drops. To monitor process capability continuously, see the EFFIX MES page or request a demo.