What Are Control Charts? X̄-R and I-MR
A control chart is a graph that shows measurements taken from a process in time order between a centre line and upper and lower control limits, visualising whether the process is in statistical control. The X̄-R chart, for subgrouped measurements, and the I-MR chart, for individual measurements, are the two most common types of control chart.
- Three lines: centre line (mean), upper control limit (UCL), lower control limit (LCL).
- Limits are calculated from process data using ±3 sigma logic; they have nothing to do with tolerance.
- X̄-R: subgroup size 2–10, the mean + range are tracked.
- I-MR: single measurement, the individual value + moving range are tracked.
- A point outside the limits or a pattern = a special cause is investigated.
What Is a Control Chart?
The control chart is the basic tool of SPC. Each measurement is plotted as a point on the graph; points scattered randomly within the limits show that the process is running with natural variation only, while a point outside the limits or a specific pattern shows that a special cause has entered the process. The chart gives an objective answer to the question “when to intervene, and when to leave it alone”.
The X̄-R Chart
It is used when more than one part is measured at each sampling moment (a subgroup, usually n = 3–5). It consists of two graphs: the X̄ chart tracks the mean of the subgroups, and the R chart tracks the difference between the largest and smallest values within the subgroup (range). The X̄ chart shows whether the centre of the process has shifted, the R chart whether the spread has grown.
| Chart | Centre | Upper limit | Lower limit |
|---|---|---|---|
| X̄ | X̿ (mean of means) | X̿ + A₂·R̄ | X̿ − A₂·R̄ |
| R | R̄ (mean of ranges) | D₄·R̄ | D₃·R̄ |
A₂, D₃ and D₄ are table constants that depend on the subgroup size. For n = 5, A₂ = 0.577, D₃ = 0 and D₄ = 2.114 are used.
The I-MR Chart
It is used when only a single measurement can be taken each time: one analysis result per batch, an hourly temperature reading, daily energy consumption and so on. The I (Individual) chart tracks the individual value, and the MR (Moving Range) chart tracks the absolute difference between two consecutive values.
| Chart | Centre | Upper limit | Lower limit |
|---|---|---|---|
| I | X̄ | X̄ + 2.66·MR̄ | X̄ − 2.66·MR̄ |
| MR | MR̄ | 3.267·MR̄ | 0 |
Because the I-MR chart does not average subgroups, it is more sensitive to noise in individual values; it does not catch small shifts as quickly as X̄-R. On the other hand, it uses every measurement immediately and is the only option when measurement is expensive or slow.
Which Chart When?
- Variable data, subgroups possible: X̄-R (n ≤ 10) or X̄-S (n > 10).
- Variable data, single measurement: I-MR.
- Attribute data, proportion defective: p or np chart.
- Attribute data, defects per part: c or u chart.
Out-of-Control Signals
Not only a point outside the limits but also the following patterns are signs of a special cause (Western Electric / Nelson rules):
- One point outside a control limit.
- 7–9 points in a row on the same side of the centre line (shift).
- 6 points in a row steadily increasing or decreasing (trend).
- 2 out of 3 points outside the 2-sigma zone.
- 14 points in a row alternating up and down (systematic oscillation).
Common Mistakes
- Deriving the limits from the tolerance; in that case the chart says nothing about the process.
- Looking at the X̄ chart first. The right way is to check the R (or MR) chart first; if the spread is unstable, the X̄ limits are meaningless too.
- Mixing measurements from different machines or shifts within a subgroup; the subgroup should be homogeneous.
- Recalculating the limits at every signal.
- Not writing down what to do when there is a signal (reaction plan).
Frequently Asked Questions
What is the difference between an X̄-R chart and an I-MR chart?
Are control limits the same as tolerance limits?
What does an out-of-control signal mean?
Control Charts in EFFIX MES
EFFIX MES automatically updates I-MR and X̄-R control charts as measurements are entered for each characteristic defined in the control plan; limits can be calculated from initial data and frozen. Measurements are collected from the HMI operator terminal or connected devices, and the same data is used in the Cp/Cpk calculation. When an out-of-control signal occurs, the Proactive Alert System can send a notification to the right person and a non-conformance record can be opened. To move your charts from paper to screen, see the EFFIX MES page or request a demo.